1. Input: 8, photoelectric isolation
2. Output: 8, optional solid-state relay output and mechanical relay output
3. Sampling rate: 50Hz
4. Sampling size: 24 bit A/D
The functions of this controller are only limited by the total number of input and output, so we can config it as following:
1. One material, four speed batching packing control
2. Two materials, three speed feeding system
3. Two materials, two speed feeding plus one material single speed feeing
4. Totalizing hopping scale controller
5. Batching weighing system using weigh-out method